[Telink] Fix TC-OPCREDS-3.6 and prevent writing to NVS during factory reset #26784

Merged
52 changes: 51 additions & 1 deletion examples/platform/telink/common/src/AppTaskCommon.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -33,6 +33,11 @@
#include "OTAUtil.h"
#endif

#ifdef CONFIG_CHIP_FACTORY_RESET_ERASE_NVS
#include <zephyr/fs/nvs.h>
#include <zephyr/settings/settings.h>
#endif

LOG_MODULE_DECLARE(app, CONFIG_CHIP_APP_LOG_LEVEL);

namespace {
Expand Down Expand Up @@ -111,7 +116,48 @@ class AppFabricTableDelegate : public FabricTable::Delegate
{
if (chip::Server::GetInstance().GetFabricTable().FabricCount() == 0)
{
chip::Server::GetInstance().ScheduleFactoryReset();
ChipLogProgress(DeviceLayer, "Performing erasing of settings partition");

#ifdef CONFIG_CHIP_FACTORY_RESET_ERASE_NVS
void * storage = nullptr;
int status = settings_storage_get(&storage);

if (status == 0)
{
status = nvs_clear(static_cast<nvs_fs *>(storage));
}

if (!status)
{
status = nvs_mount(static_cast<nvs_fs *>(storage));
}

if (status)
{
ChipLogError(DeviceLayer, "Storage clearance failed: %d", status);
}
#else
const CHIP_ERROR err = PersistedStorage::KeyValueStoreMgrImpl().DoFactoryReset();

if (err != CHIP_NO_ERROR)
{
ChipLogError(DeviceLayer, "Factory reset failed: %" CHIP_ERROR_FORMAT, err.Format());
}

ConnectivityMgr().ErasePersistentInfo();
#endif
}
}
};

class PlatformMgrDelegate : public DeviceLayer::PlatformManagerDelegate
{
void OnShutDown() override
{
if (ThreadStackManagerImpl().IsThreadEnabled())
{
ThreadStackManagerImpl().SetThreadEnabled(false);
ThreadStackManagerImpl().SetRadioBlocked(true);
}
}
};
Expand Down Expand Up @@ -229,6 +275,10 @@ CHIP_ERROR AppTaskCommon::InitCommonParts(void)
emberAfEndpointEnableDisable(kNetworkCommissioningEndpointSecondary, false);
#endif

// We need to disable OpenThread to prevent writing to the NVS storage when factory reset occurs
// For this the OnShutdown function is used
PlatformMgr().SetDelegate(new PlatformMgrDelegate);

// Add CHIP event handler and start CHIP thread.
// Note that all the initialization code should happen prior to this point to avoid data races
// between the main and the CHIP threads.