We should calculate efficiency calculations on the backend. @aforbis-stokes had the following snippet to inform the calculations to be made:
// Script for diagnostics
#define HXCI A0 // Heat Exchanger Cold Inlet
#define HXCO A1 // Heat Exchanger Cold Output
#define HTR A2 // Heater
#define HXHI A3 // Heat Exchanger Hot Inlet
#define HXHO A4 // Heat Exchanger Hot Outlet
#define PUMP D0
#define VALVE D1
#define IGNITOR D2
#define BUCKET C4
#define STEP D6
#define DIR D5
#define SLEEP D3
#define UP B5
#define DOWN C3
#define RESET C2
#define SD_CS_PIN B3
#define SD_CD_PIN B4
#define SD_DI_PIN B2
#define SD_DO_PIN B1
#define SD_CLK_PIN B0
//New definitions
#define DH // Dome height [cm], user input
#define CX_DH // Dome height cross-sectional area [cm2]
#define Q_WASTE // Waste (liquid) flow
#define Q_GAS // Biogas flow, [ccm], user input
#define TB_volume 0.325 // Tipping bucket volume conversion, L/tip
#define ValveStatus // Gas valve status, 1=open, 0=closed
#define C_p 4.19 // [kJ/L/degC]
#define U_gas 36.8 // Energy concent of methane [kJ/L]
#define CH4 0.60 // Fraction of biogas in methane
#define CODconc 42 // gCOD/Lwaste, based on location and flush volume
#define HTR_volume 8.7 // [L]
//Calculate the following for each day:
Q_WASTE = tips*TB_volume / last_publish_time
Biogas_used = AVG(ValveStatus)*AVG(Q_GAS) // [L]
Biogas_prod = ((DH1-DH0)*CX_DH + Q_GAS*AVG(ValveStatus)*(t1-t0)) / (t1-t0)
//Gas production as fxn of change of storage volume and gas usage for given day
//"1" and "0" are based manual entries for current day and previous day
Yield = Biogas_prod / (Q_WASTE/CODconc) //[Lgas/gCOD]
Heater_power = (tempHTR-tempHXCO)*Q_WASTE*C_p // measured gain, [kJ/d] convert to [W]
Gas_power = (Biogas_used*CH4*U_gas) // theo. power input, [kJ/d] convert to [W]
Heater_effic = Heater_power/Gas_power // efficiency of full heater (not burner)
HXcold_power = (HXCO-HXCI)*Q_WASTE*C_p // power gain in HX, [kJ/d] convert to [W]
HXhot_power_loss = (HXHO-HXHI)*Q_WASTE*C_p // power loss from HXhot, [kJ/d] convert to [W]
HX_effic = HXcold_power/HXhot_power_loss // How much heat goes from hot to cold
HX_recovery_effic = HXcold_power/Heater_power // How much of total heat is recovered
if tips = 0 && ValveStatus=0 for 30 min
then Loss = (HTR1-HTR0)*HTR_volume*C_p / (t1-t0) // decrease in temp over last 30 min
Burner_effic = (Heater_power+Loss) / Gas_power
//On-demand variables for troubleshooting
All temps & ValveStatus
Burner_effic // provide for last 6 readings
//use AVG(Loss) of last 20 values
//consider interrupt function for troubleshooting, read every 20s instead of 2.5 min
Heater_effic
//Error logs
if tempHTR < 62 for 15 minutes
if Heater_effic < 50
if Burner_effic < 75
if Q_WASTE < 0.5*OPTIMAL_FLOW*24 //OPTIMAL_FLOW is set in main in [L/hr]