Skip to content

Commit

Permalink
Improvement: DPL: encapsulate SolarPassThrough check
Browse files Browse the repository at this point in the history
  • Loading branch information
AndreasBoehm authored and schlimmchen committed Feb 10, 2025
1 parent 4c67399 commit 3858004
Show file tree
Hide file tree
Showing 2 changed files with 13 additions and 7 deletions.
1 change: 1 addition & 0 deletions include/PowerLimiter.h
Original file line number Diff line number Diff line change
Expand Up @@ -105,6 +105,7 @@ class PowerLimiterClass {
bool isStopThresholdReached();
bool isBelowStopThreshold();
void calcNextInverterRestart();
bool isSolarPassThroughEnabled();
bool isFullSolarPassthroughActive();
};

Expand Down
19 changes: 12 additions & 7 deletions src/PowerLimiter.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -317,7 +317,7 @@ void PowerLimiterClass::loop()
config.PowerLimiter.VoltageStopThreshold,
config.PowerLimiter.BatterySocStopThreshold);

if (config.SolarCharger.Enabled && config.PowerLimiter.SolarPassThroughEnabled) {
if (isSolarPassThroughEnabled()) {
MessageOutput.printf("[DPL] full solar-passthrough %s, start %.2f V or %u %%, stop %.2f V\r\n",
(isFullSolarPassthroughActive()?"active":"dormant"),
config.PowerLimiter.FullSolarPassThroughStartVoltage,
Expand All @@ -328,7 +328,7 @@ void PowerLimiterClass::loop()
MessageOutput.printf("[DPL] start %sreached, stop %sreached, solar-passthrough %sabled, use at night %sabled and %s\r\n",
(isStartThresholdReached()?"":"NOT "),
(isStopThresholdReached()?"":"NOT "),
(config.PowerLimiter.SolarPassThroughEnabled?"en":"dis"),
(isSolarPassThroughEnabled()?"en":"dis"),
(config.PowerLimiter.BatteryAlwaysUseAtNight?"en":"dis"),
(_nighttimeDischarging?"active":"dormant"));

Expand Down Expand Up @@ -714,11 +714,9 @@ bool PowerLimiterClass::updateInverters()

uint16_t PowerLimiterClass::getSolarPassthroughPower()
{
auto const& config = Configuration.get();
auto solarChargerOutput = SolarCharger.getStats()->getOutputPowerWatts();

if (!config.SolarCharger.Enabled
|| !config.PowerLimiter.SolarPassThroughEnabled
if (!isSolarPassThroughEnabled()
|| isBelowStopThreshold()
|| !solarChargerOutput
) {
Expand Down Expand Up @@ -885,7 +883,7 @@ void PowerLimiterClass::calcNextInverterRestart()
_nextInverterRestart = { true, restartMillis };
}

bool PowerLimiterClass::isFullSolarPassthroughActive()
bool PowerLimiterClass::isSolarPassThroughEnabled()
{
auto const& config = Configuration.get();

Expand All @@ -895,8 +893,15 @@ bool PowerLimiterClass::isFullSolarPassthroughActive()
// solarcharger is needed for solar passthrough
if (!config.SolarCharger.Enabled) { return false; }

return config.PowerLimiter.SolarPassThroughEnabled;
}

bool PowerLimiterClass::isFullSolarPassthroughActive()
{
auto const& config = Configuration.get();

// We only do full solar PT if general solar PT is enabled
if (!config.PowerLimiter.SolarPassThroughEnabled) { return false; }
if (!isSolarPassThroughEnabled()) { return false; }

if (testThreshold(config.PowerLimiter.FullSolarPassThroughSoc,
config.PowerLimiter.FullSolarPassThroughStartVoltage,
Expand Down