Skip to content

Commit

Permalink
Fix OCSP test responder to omit fractional seconds
Browse files Browse the repository at this point in the history
  • Loading branch information
vcsjones authored Oct 25, 2022
1 parent 0bb8df7 commit f4b715f
Showing 1 changed file with 11 additions and 2 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -566,9 +566,18 @@ singleExtensions [1] EXPLICIT Extensions OPTIONAL }
}
else if (status == CertStatus.Revoked)
{
// Android does not support all precisions for seconds - just omit fractional seconds for testing on Android
writer.PushSequence(s_context1);
writer.WriteGeneralizedTime(revokedTime, omitFractionalSeconds: OperatingSystem.IsAndroid());

// Fracational seconds "MUST NOT" be used here. Android and macOS 13+ enforce this and
// reject GeneralizedTime's with fractional seconds, so omit them.
// RFC 6960: 4.2.2.1:
// The format for GeneralizedTime is as specified in Section 4.1.2.5.2 of [RFC5280].
// RFC 5280 4.1.2.5.2:
// For the purposes of this profile, GeneralizedTime values MUST be
// expressed in Greenwich Mean Time (Zulu) and MUST include seconds
// (i.e., times are YYYYMMDDHHMMSSZ), even where the number of seconds
// is zero. GeneralizedTime values MUST NOT include fractional seconds.
writer.WriteGeneralizedTime(revokedTime, omitFractionalSeconds: true);
writer.PopSequence(s_context1);
}
else
Expand Down

0 comments on commit f4b715f