Fixed bugs related to volumetric heat capacity of water #574
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
VIC4.2
- the hardcoded number4186.8
here should be volumetric heat of water (which is 4186.8e3): https://github.com/UW-Hydro/VIC/blob/support/VIC.4.2.d/src/func_canopy_energy_bal.c#L262 . Other places inVIC4.2
related to volumetric heat of water appear to be correct)