Select commit Hold shift + click to select a range
66ebdb1
add new test files
yzhou601 Nov 18, 2023
1b00e68
first cut to implement autosizing detailed performance data
yzhou601 Dec 8, 2023
83c2193
Merge branch 'master' of https://github.com/NREL/OpenStudio-HPXML int…
yzhou601 Dec 8, 2023
315d22a
require nominal cooling heating capacities when capacities are provid…
yzhou601 Dec 8, 2023
f59feb3
Merge branch 'master' of https://github.com/NREL/OpenStudio-HPXML int…
yzhou601 Jan 3, 2024
21f675c
fixed ci error and added a test for capacity and capacity fractions
yzhou601 Jan 9, 2024
ebcc65c
update hpxmls
yzhou601 Jan 9, 2024
5d9aa74
Merge branch 'master' of https://github.com/NREL/OpenStudio-HPXML int…
yzhou601 Jan 9, 2024
d475647
Merge branch 'master' of https://github.com/NREL/OpenStudio-HPXML int…
yzhou601 Jan 10, 2024
7b1c6ee
docs and changelog
yzhou601 Jan 10, 2024
c3fdc07
update_measures
yzhou601 Jan 10, 2024
2be3174
Merge branch 'master' of https://github.com/NREL/OpenStudio-HPXML int…
shorowit Jan 18, 2024
14fd75b
Small fix, noticed by @joseph-robertson.
shorowit Jan 18, 2024
6c5cedc
reconfigure a test file
yzhou601 Jan 18, 2024
69730d7
Merge branch 'autosizing_detailed_performance' of https://github.com/…
yzhou601 Jan 18, 2024
9587aeb
Latest results.
Jan 19, 2024
c75b04a
New build test for perf data with apply_defaults=true.
joseph-robertson Jan 19, 2024
bafce27
Convert dps to floats and test passes.
joseph-robertson Jan 23, 2024
ff419d5
Merge branch 'master' into autosizing_detailed_performance
joseph-robertson Jan 23, 2024
1bffa2c
Merge branch 'master' of https://github.com/NREL/OpenStudio-HPXML int…
shorowit Jan 24, 2024
b655081
address comments
yzhou601 Jan 24, 2024
7e7d7f0
Latest results.
Jan 25, 2024
c8dfaa7
address comments related to docs
yzhou601 Jan 25, 2024
a473172
Merge branch 'autosizing_detailed_performance' of https://github.com/…
yzhou601 Jan 25, 2024
26f7378
Merge branch 'master' of https://github.com/NREL/OpenStudio-HPXML int…
shorowit Jan 25, 2024
19f740d
Minor docs cleanup.
shorowit Jan 25, 2024
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
2 changes: 1 addition & 1 deletion BuildResidentialHPXML/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -2287,7 +2287,7 @@ Type of capacity values for detailed performance data if available. Applies only

- **Required:** ``false``

- **Choices:** `Absolute capacities`
- **Choices:** `Absolute capacities`, `Normalized capacity fractions`

<br/>

Expand Down
53 changes: 25 additions & 28 deletions BuildResidentialHPXML/measure.rb
Original file line number Diff line number Diff line change
Expand Up @@ -1384,7 +1384,7 @@ def arguments(model) # rubocop:disable Lint/UnusedMethodArgument

perf_data_capacity_type_choices = OpenStudio::StringVector.new
perf_data_capacity_type_choices << 'Absolute capacities'
# perf_data_capacity_type_choices << 'Normalized capacity fractions'
perf_data_capacity_type_choices << 'Normalized capacity fractions'

arg = OpenStudio::Measure::OSArgument.makeChoiceArgument('hvac_perf_data_capacity_type', perf_data_capacity_type_choices, false)
arg.setDisplayName('HVAC Detailed Performance Data: Capacity Type')
Expand Down Expand Up @@ -5232,23 +5232,23 @@ def self.set_cooling_systems(hpxml_bldg, args)
outdoor_temperature, min_speed_cap_or_frac, max_speed_cap_or_frac, min_speed_cop, max_speed_cop = cooling_perf_data_data_point

if hvac_perf_data_capacity_type == 'Absolute capacities'
min_speed_capacity = min_speed_cap_or_frac
max_speed_capacity = max_speed_cap_or_frac
min_speed_capacity = Float(min_speed_cap_or_frac)
max_speed_capacity = Float(max_speed_cap_or_frac)
elsif hvac_perf_data_capacity_type == 'Normalized capacity fractions'
min_speed_capacity_fraction_of_nominal = min_speed_cap_or_frac
max_speed_capacity_fraction_of_nominal = max_speed_cap_or_frac
min_speed_capacity_fraction_of_nominal = Float(min_speed_cap_or_frac)
max_speed_capacity_fraction_of_nominal = Float(max_speed_cap_or_frac)
end

clg_perf_data.add(outdoor_temperature: outdoor_temperature,
clg_perf_data.add(outdoor_temperature: Float(outdoor_temperature),
capacity: min_speed_capacity,
capacity_fraction_of_nominal: min_speed_capacity_fraction_of_nominal,
capacity_description: HPXML::CapacityDescriptionMinimum,
efficiency_cop: min_speed_cop)
clg_perf_data.add(outdoor_temperature: outdoor_temperature,
efficiency_cop: Float(min_speed_cop))
clg_perf_data.add(outdoor_temperature: Float(outdoor_temperature),
capacity: max_speed_capacity,
capacity_fraction_of_nominal: max_speed_capacity_fraction_of_nominal,
capacity_description: HPXML::CapacityDescriptionMaximum,
efficiency_cop: max_speed_cop)
efficiency_cop: Float(max_speed_cop))
end
end
end
Expand Down Expand Up @@ -5413,28 +5413,25 @@ def self.set_heat_pumps(hpxml_bldg, args)
outdoor_temperature, min_speed_cap_or_frac, max_speed_cap_or_frac, min_speed_cop, max_speed_cop = heating_perf_data_data_point

if hvac_perf_data_capacity_type == 'Absolute capacities'
min_speed_capacity = min_speed_cap_or_frac
max_speed_capacity = max_speed_cap_or_frac
min_speed_capacity = Float(min_speed_cap_or_frac)
max_speed_capacity = Float(max_speed_cap_or_frac)
elsif hvac_perf_data_capacity_type == 'Normalized capacity fractions'
min_speed_capacity_fraction_of_nominal = min_speed_cap_or_frac
max_speed_capacity_fraction_of_nominal = max_speed_cap_or_frac
min_speed_capacity_fraction_of_nominal = Float(min_speed_cap_or_frac)
max_speed_capacity_fraction_of_nominal = Float(max_speed_cap_or_frac)
end

htg_perf_data.add(outdoor_temperature: outdoor_temperature,
htg_perf_data.add(outdoor_temperature: Float(outdoor_temperature),
capacity: min_speed_capacity,
capacity_fraction_of_nominal: min_speed_capacity_fraction_of_nominal,
capacity_description: HPXML::CapacityDescriptionMinimum,
efficiency_cop: min_speed_cop)
htg_perf_data.add(outdoor_temperature: outdoor_temperature,
efficiency_cop: Float(min_speed_cop))
htg_perf_data.add(outdoor_temperature: Float(outdoor_temperature),
capacity: max_speed_capacity,
capacity_fraction_of_nominal: max_speed_capacity_fraction_of_nominal,
capacity_description: HPXML::CapacityDescriptionMaximum,
efficiency_cop: max_speed_cop)
efficiency_cop: Float(max_speed_cop))
end
end

if args[:hvac_perf_data_capacity_type].is_initialized
hvac_perf_data_capacity_type = args[:hvac_perf_data_capacity_type].get
hvac_perf_data_cooling_outdoor_temperatures = args[:hvac_perf_data_cooling_outdoor_temperatures].get.split(',').map(&:strip)
hvac_perf_data_cooling_min_speed_capacities = args[:hvac_perf_data_cooling_min_speed_capacities].get.split(',').map(&:strip)
hvac_perf_data_cooling_max_speed_capacities = args[:hvac_perf_data_cooling_max_speed_capacities].get.split(',').map(&:strip)
Expand All @@ -5450,23 +5447,23 @@ def self.set_heat_pumps(hpxml_bldg, args)
outdoor_temperature, min_speed_cap_or_frac, max_speed_cap_or_frac, min_speed_cop, max_speed_cop = cooling_perf_data_data_point

if hvac_perf_data_capacity_type == 'Absolute capacities'
min_speed_capacity = min_speed_cap_or_frac
max_speed_capacity = max_speed_cap_or_frac
min_speed_capacity = Float(min_speed_cap_or_frac)
max_speed_capacity = Float(max_speed_cap_or_frac)
elsif hvac_perf_data_capacity_type == 'Normalized capacity fractions'
min_speed_capacity_fraction_of_nominal = min_speed_cap_or_frac
max_speed_capacity_fraction_of_nominal = max_speed_cap_or_frac
min_speed_capacity_fraction_of_nominal = Float(min_speed_cap_or_frac)
max_speed_capacity_fraction_of_nominal = Float(max_speed_cap_or_frac)
end

clg_perf_data.add(outdoor_temperature: outdoor_temperature,
clg_perf_data.add(outdoor_temperature: Float(outdoor_temperature),
capacity: min_speed_capacity,
capacity_fraction_of_nominal: min_speed_capacity_fraction_of_nominal,
capacity_description: HPXML::CapacityDescriptionMinimum,
efficiency_cop: min_speed_cop)
clg_perf_data.add(outdoor_temperature: outdoor_temperature,
efficiency_cop: Float(min_speed_cop))
clg_perf_data.add(outdoor_temperature: Float(outdoor_temperature),
capacity: max_speed_capacity,
capacity_fraction_of_nominal: max_speed_capacity_fraction_of_nominal,
capacity_description: HPXML::CapacityDescriptionMaximum,
efficiency_cop: max_speed_cop)
efficiency_cop: Float(max_speed_cop))
end
end
end
Expand Down
14 changes: 9 additions & 5 deletions BuildResidentialHPXML/measure.xml
Original file line number Diff line number Diff line change
Expand Up @@ -3,8 +3,8 @@
<schema_version>3.1</schema_version>
<name>build_residential_hpxml</name>
<uid>a13a8983-2b01-4930-8af2-42030b6e4233</uid>
<version_id>54215a14-93ab-4f56-b310-4fdb6cc374e9</version_id>
<version_modified>2024-01-17T16:52:35Z</version_modified>
<version_id>dc0de2f1-fea3-4b8e-9df9-579c3fcc74dc</version_id>
<version_modified>2024-01-23T20:04:33Z</version_modified>
<xml_checksum>2C38F48B</xml_checksum>
<class_name>BuildResidentialHPXML</class_name>
<display_name>HPXML Builder</display_name>
Expand Down Expand Up @@ -2898,6 +2898,10 @@
<value>Absolute capacities</value>
<display_name>Absolute capacities</display_name>
</choice>
<choice>
<value>Normalized capacity fractions</value>
<display_name>Normalized capacity fractions</display_name>
</choice>
</choices>
</argument>
<argument>
Expand Down Expand Up @@ -7110,7 +7114,7 @@
<filename>README.md</filename>
<filetype>md</filetype>
<usage_type>readme</usage_type>
<checksum>3BA4B197</checksum>
<checksum>4F99980F</checksum>
</file>
<file>
<filename>README.md.erb</filename>
Expand All @@ -7127,7 +7131,7 @@
<filename>measure.rb</filename>
<filetype>rb</filetype>
<usage_type>script</usage_type>
<checksum>EEE134EA</checksum>
<checksum>5D65A1D1</checksum>
</file>
<file>
<filename>geometry.rb</filename>
Expand All @@ -7139,7 +7143,7 @@
<filename>test_build_residential_hpxml.rb</filename>
<filetype>rb</filetype>
<usage_type>test</usage_type>
<checksum>03168F56</checksum>
<checksum>FC9E4B75</checksum>
</file>
</files>
</measure>
22 changes: 22 additions & 0 deletions BuildResidentialHPXML/tests/test_build_residential_hpxml.rb
Original file line number Diff line number Diff line change
Expand Up @@ -68,6 +68,7 @@ def test_workflows
'extra-water-heater-attic.xml' => 'base-sfd.xml',
'extra-battery-crawlspace.xml' => 'base-sfd.xml',
'extra-battery-attic.xml' => 'base-sfd.xml',
'extra-detailed-performance-autosize.xml' => 'base-sfd.xml',

'extra-sfa-atticroof-flat.xml' => 'base-sfa.xml',
'extra-sfa-atticroof-conditioned-eaves-gable.xml' => 'extra-sfa-slab.xml',
Expand Down Expand Up @@ -915,6 +916,27 @@ def _set_measure_argument_values(hpxml_file, args)
elsif ['extra-battery-attic.xml'].include? hpxml_file
args['battery_present'] = true
args['battery_location'] = HPXML::LocationAttic
elsif ['extra-detailed-performance-autosize.xml'].include? hpxml_file
args['heating_system_type'] = 'none'
args['cooling_system_type'] = 'none'
args['heat_pump_type'] = HPXML::HVACTypeHeatPumpAirToAir
args['heat_pump_heating_efficiency'] = 10.0
args['heat_pump_cooling_efficiency'] = 17.25
args['heat_pump_cooling_compressor_type'] = HPXML::HVACCompressorTypeVariableSpeed
args['heat_pump_cooling_sensible_heat_fraction'] = 0.78
args.delete('heat_pump_heating_capacity')
args.delete('heat_pump_cooling_capacity')
args['hvac_perf_data_capacity_type'] = 'Normalized capacity fractions'
args['hvac_perf_data_heating_outdoor_temperatures'] = '47.0, 17.0, 5.0'
args['hvac_perf_data_heating_min_speed_capacities'] = '0.28, 0.12, 0.05'
args['hvac_perf_data_heating_max_speed_capacities'] = '1.0, 0.69, 0.55'
args['hvac_perf_data_heating_min_speed_cops'] = '4.73, 1.84, 0.81'
args['hvac_perf_data_heating_max_speed_cops'] = '3.44, 2.66, 2.28'
args['hvac_perf_data_cooling_outdoor_temperatures'] = '95.0, 82.0'
args['hvac_perf_data_cooling_min_speed_capacities'] = '0.325, 0.37'
args['hvac_perf_data_cooling_max_speed_capacities'] = '1.0, 1.11'
args['hvac_perf_data_cooling_min_speed_cops'] = '4.47, 6.34'
args['hvac_perf_data_cooling_max_speed_cops'] = '2.71, 3.53'
elsif ['extra-sfa-atticroof-flat.xml'].include? hpxml_file
args['geometry_attic_type'] = HPXML::AtticTypeFlatRoof
args['ducts_supply_leakage_to_outside_value'] = 0.0
Expand Down
1 change: 1 addition & 0 deletions Changelog.md
Original file line number Diff line number Diff line change
Expand Up @@ -12,6 +12,7 @@ __New Features__
- BuildResidentialHPXML measure:
- **Breaking change**: Replaces `roof_radiant_barrier`/`roof_radiant_barrier_grade` arguments with `radiant_barrier_attic_location`/`radiant_barrier_grade`.
- Adds detailed performance data inputs for variable-speed air source HVAC systems.
- Allows autosizing with detailed performance data inputs for variable-speed air source HVAC systems using `CapacityFractionOfNominal`.
- Add soil and moisture type arguments (for determining ground conductivity and diffusivity) and optional geothermal loop arguments for ground source heat pumps.
- The "Geometry: Building Number of Units" input is now written to the HPXML `NumberofUnitsInBuilding` element.
- Updated water heater installation location defaulting to match ANSI 301-2022
Expand Down
16 changes: 8 additions & 8 deletions HPXMLtoOpenStudio/measure.xml
Original file line number Diff line number Diff line change
Expand Up @@ -3,8 +3,8 @@
<schema_version>3.1</schema_version>
<name>hpxm_lto_openstudio</name>
<uid>b1543b30-9465-45ff-ba04-1d1f85e763bc</uid>
<version_id>e8f6fe19-6923-4754-9d02-8613aca2a5ab</version_id>
<version_modified>2024-01-23T20:12:50Z</version_modified>
<version_id>c9c5edc9-476a-41aa-942b-137b3ac923aa</version_id>
<version_modified>2024-01-24T15:37:38Z</version_modified>
<xml_checksum>D8922A73</xml_checksum>
<class_name>HPXMLtoOpenStudio</class_name>
<display_name>HPXML to OpenStudio Translator</display_name>
Expand Down Expand Up @@ -310,7 +310,7 @@
<filename>hpxml_defaults.rb</filename>
<filetype>rb</filetype>
<usage_type>resource</usage_type>
<checksum>916525C3</checksum>
<checksum>9E603DB1</checksum>
</file>
<file>
<filename>hpxml_schema/HPXML.xsd</filename>
Expand All @@ -328,7 +328,7 @@
<filename>hpxml_schematron/EPvalidator.xml</filename>
<filetype>xml</filetype>
<usage_type>resource</usage_type>
<checksum>85D88CDE</checksum>
<checksum>7EE89A2E</checksum>
</file>
<file>
<filename>hpxml_schematron/iso-schematron.xsd</filename>
Expand All @@ -340,13 +340,13 @@
<filename>hvac.rb</filename>
<filetype>rb</filetype>
<usage_type>resource</usage_type>
<checksum>4CEA3B45</checksum>
<checksum>A060839F</checksum>
</file>
<file>
<filename>hvac_sizing.rb</filename>
<filetype>rb</filetype>
<usage_type>resource</usage_type>
<checksum>94E05F98</checksum>
<checksum>7CE7B6AB</checksum>
</file>
<file>
<filename>lighting.rb</filename>
Expand Down Expand Up @@ -592,7 +592,7 @@
<filename>test_defaults.rb</filename>
<filetype>rb</filetype>
<usage_type>test</usage_type>
<checksum>EF0F0416</checksum>
<checksum>75775259</checksum>
</file>
<file>
<filename>test_enclosure.rb</filename>
Expand Down Expand Up @@ -664,7 +664,7 @@
<filename>test_validation.rb</filename>
<filetype>rb</filetype>
<usage_type>test</usage_type>
<checksum>C564EC22</checksum>
<checksum>D799B100</checksum>
</file>
<file>
<filename>test_water_heater.rb</filename>
Expand Down
38 changes: 28 additions & 10 deletions HPXMLtoOpenStudio/resources/hpxml_defaults.rb
Original file line number Diff line number Diff line change
Expand Up @@ -1241,17 +1241,9 @@ def self.apply_hvac(runner, hpxml, hpxml_bldg, weather, convert_shared_systems)
next unless heat_pump.heating_capacity_retention_fraction.nil?
next unless heat_pump.heating_capacity_17F.nil?
next if [HPXML::HVACTypeHeatPumpGroundToAir, HPXML::HVACTypeHeatPumpWaterLoopToAir].include? heat_pump.heat_pump_type
next unless heat_pump.heating_detailed_performance_data.empty? # set after hvac sizing

if not heat_pump.heating_detailed_performance_data.empty?
# Calculate heating capacity retention at 5F outdoor drybulb
target_odb = 5.0
max_capacity_47 = heat_pump.heating_detailed_performance_data.find { |dp| dp.outdoor_temperature == HVAC::AirSourceHeatRatedODB && dp.capacity_description == HPXML::CapacityDescriptionMaximum }.capacity
heat_pump.heating_capacity_retention_fraction = (HVAC.interpolate_to_odb_table_point(heat_pump.heating_detailed_performance_data, HPXML::CapacityDescriptionMaximum, target_odb, :capacity) / max_capacity_47).round(5)
heat_pump.heating_capacity_retention_fraction = 0.0 if heat_pump.heating_capacity_retention_fraction < 0
heat_pump.heating_capacity_retention_temp = target_odb
else
heat_pump.heating_capacity_retention_temp, heat_pump.heating_capacity_retention_fraction = HVAC.get_default_heating_capacity_retention(heat_pump.compressor_type, heat_pump.heating_efficiency_hspf)
end
heat_pump.heating_capacity_retention_temp, heat_pump.heating_capacity_retention_fraction = HVAC.get_default_heating_capacity_retention(heat_pump.compressor_type, heat_pump.heating_efficiency_hspf)
heat_pump.heating_capacity_retention_fraction_isdefaulted = true
heat_pump.heating_capacity_retention_temp_isdefaulted = true
end
Expand Down Expand Up @@ -1672,6 +1664,13 @@ def self.apply_detailed_performance_data_for_var_speed_systems(hpxml_bldg)
if hvac_system.cooling_detailed_performance_data.empty?
HVAC.set_cool_detailed_performance_data(hvac_system)
else
# process capacity fraction of nominal
hvac_system.cooling_detailed_performance_data.each do |dp|
next unless dp.capacity.nil?

dp.capacity = dp.capacity_fraction_of_nominal * hvac_system.cooling_capacity
end

# override some properties based on detailed performance data
cool_rated_capacity = [hvac_system.cooling_capacity, 1.0].max
cool_max_capacity = [hvac_system.cooling_detailed_performance_data.find { |dp| (dp.outdoor_temperature == HVAC::AirSourceCoolRatedODB) && (dp.capacity_description == HPXML::CapacityDescriptionMaximum) }.capacity, 1.0].max
Expand All @@ -1683,6 +1682,21 @@ def self.apply_detailed_performance_data_for_var_speed_systems(hpxml_bldg)
if hvac_system.heating_detailed_performance_data.empty?
HVAC.set_heat_detailed_performance_data(hvac_system)
else
# process capacity fraction of nominal
hvac_system.heating_detailed_performance_data.each do |dp|
next unless dp.capacity.nil?

dp.capacity = dp.capacity_fraction_of_nominal * hvac_system.heating_capacity
end

if hvac_system.heating_capacity_retention_fraction.nil? && hvac_system.heating_capacity_17F.nil?
# Calculate heating capacity retention at 5F outdoor drybulb
target_odb = 5.0
max_capacity_47 = hvac_system.heating_detailed_performance_data.find { |dp| dp.outdoor_temperature == HVAC::AirSourceHeatRatedODB && dp.capacity_description == HPXML::CapacityDescriptionMaximum }.capacity
hvac_system.heating_capacity_retention_fraction = (HVAC.interpolate_to_odb_table_point(hvac_system.heating_detailed_performance_data, HPXML::CapacityDescriptionMaximum, target_odb, :capacity) / max_capacity_47).round(5)
hvac_system.heating_capacity_retention_fraction = 0.0 if hvac_system.heating_capacity_retention_fraction < 0
hvac_system.heating_capacity_retention_temp = target_odb
end
# override some properties based on detailed performance data
heat_rated_capacity = [hvac_system.heating_capacity, 1.0].max
heat_max_capacity = [hvac_system.heating_detailed_performance_data.find { |dp| (dp.outdoor_temperature == HVAC::AirSourceHeatRatedODB) && (dp.capacity_description == HPXML::CapacityDescriptionMaximum) }.capacity, 1.0].max
Expand Down Expand Up @@ -3071,6 +3085,8 @@ def self.apply_hvac_sizing(runner, hpxml_bldg, weather, cfa)
if not htg_sys.heating_detailed_performance_data.empty?
# Fixed values entered; Scale w/ heating_capacity in case allow_increased_fixed_capacities=true
htg_sys.heating_detailed_performance_data.each do |dp|
next if dp.capacity.nil? # using autosized values, process later

htg_cap_dp = dp.capacity * scaling_factor
if (dp.capacity - htg_cap_dp).abs >= 1.0
dp.capacity = Float(htg_cap_dp.round)
Expand Down Expand Up @@ -3135,6 +3151,8 @@ def self.apply_hvac_sizing(runner, hpxml_bldg, weather, cfa)
scaling_factor = Float(hvac_sizing_values.Cool_Capacity.round) / clg_sys.cooling_capacity unless clg_sys.cooling_capacity.nil?
# Fixed values entered; Scale w/ cooling_capacity in case allow_increased_fixed_capacities=true
clg_sys.cooling_detailed_performance_data.each do |dp|
next if dp.capacity.nil? # using autosized values

clg_cap_dp = dp.capacity * scaling_factor
if (dp.capacity - clg_cap_dp).abs >= 1.0
dp.capacity = Float(clg_cap_dp.round)
Expand Down