Quirks between CODESYS PlcOpenXml data and B&R Automation studio

Here we list all the known quirks and differences between the source and the B&R Automation studio

Libraries

  • Version attribute can only be in format X.YY.Z

Data types

String conversion

XX_TO_STRING(Var) can only be saved into a variable. If the function returns to a function parameter or an expression the compiler will raise an error. Use a temporary variable to save the result of the function and then pass it to the parameter or expression.

Var files

  • All variables here are constants
  • Even though the data types of the constant have values they need to be initialized

Function blocks

Functions

B&R function cannot return a string, array or a struct but Codesys can. These functions need to be converted that they return a BOOL and add a VAR_IN_OUT where the correct return result will be stored. This problem is solved partially by the automatic porter and the return value must be fixed manually

Usage in CODESYS -> vResult := TO_UPPER(vSomeString); Usage in B&R -> TO_UPPER(vSomeString, vResult);

Pous in general

  • Codesys uses syntax POINTER TO while AS uses REFERENCE TO. This problem is solved during the automatic porting
  • Pointer dereferencing is not the same between systems. Needs to be fixed manually
  • All identifiers like variables, functions, data types etc are case sensitive. Some problems have been fixed with the script
  • Many pous use the variable edge which is a protected keyword. use edge_
  • syntax for array and string sizes and also POUs like OSCAT_BASIC.STRING_LENGHT is converted to be just STRING_LENGHT as the library holding this constant needs to be added as dependency library
  • END_IF;,END_CASE;, END_FOR; and END_WHILE; statements do not need a semicolon at the end. This is fixed with the script
  • VAR_INPUT CONSTANT doesnt exist in automation studio. These need to be figured out what we do with them
  • BYTE + BYTE is not possible
  • DWORD + DWORD is not possible
  • If ADR() is used, resulting data type must be UDINT
  • A function or function block from an IEC library is attempting to access a component of a constant structure or an element of a constant array. Only constant variables with elementary data types can be accessed. MATH.PI doesnt work

Pointers

ADDRESSING

In codesys: PT := ADR(Var); In B&R: PT ACCESS ADR(Var);

DEREFERENCING

In codesys: PT^ := 0; In B&R: PT := 0;