LinkNodeR4 firmware

Documentation

The following MQTT topics are subscribed to by the client;

  • HeatingControl/heartbeat - A heartbeat to tell the relay the controller is alive.
  • HeatingControl/Cmd/Relay1 - 1 switches relay on, 0 switches it off
  • HeatingControl/Cmd/Relay2
  • HeatingControl/Cmd/Relay3
  • HeatingControl/Cmd/Relay4

The following topics are published by the LinkNodeR4 - this is the state the system knows the relays are in:

  • HeatingControl/Status/Status
  • HeatingControl/Status/Relay1
  • HeatingControl/Status/Relay2
  • HeatingControl/Status/Relay3
  • HeatingControl/Status/Relay4

Put your own values for Wifi and IP address in. An IP address of 0.0.0.0 will force DHCP. Save the file as 'LocalSettings.hpp'. This will be ignored by git.