-- Prints faults to the System Fault Log. The System Fault Log is non volatile so will
-- withstand a reboot of the equipment. Can be helpfull when a fault with the system has caused
-- an outage of some kind.
--Initialise
status = Controls.Status
val = Controls.Value
fault = Controls.Fault_Status
----------------------
--Eventhandlers
-------------------------
--status
for i = 1, #status do
status[i].EventHandler = function ()
fault = ' | status '..i..' fault'
resolved = ' | status '..i..' resolved'
if status[i].Boolean == true then
print(os.date()..fault)
else
print(os.date()..resolved)
end
end
end
--value
for k = 1, #val do
val[k].EventHandler = function ()
v = val[k].String
print(os.date()..' | value '..k..' mode'..v)
end
end
--fault status
fault.EventHandler = function ()
print(os.date()..' | '..fault.String)
end